Voltage Protection: |
 |
Whenever
source power falls below 104 Volts, or
rises above 132 volts, the EMS
automatically shuts down power to the RV.
Once the AC source rises above 104-volts, or
below the 132-volt level, the time delay
indicator flashes for the preset time and then
automatically restores power to RV.
 |
Time Delay for A/C Compressor: |
 |
Whenever
source power is interrupted by
the source or the EMS due to a fault
condition, the built in time delay is
activated for 136 seconds.
 |
Five(5)-Mode Surge Protection: |
 |
This
feature provides full surge protection:
L-N, L-N, L-G, L-G, and N-G. Total Joule
rating is 3560, response time of <1 nano second.
 |
Surge Indicator: |
 |
If ever
a power surge damages the surge
protector circuit within the EMS L-N, or L-G, the
digital display error code will read E-10. This
is your indication that it needs to be replaced.
 |
Reverse Polarity Protection: |
 |
If
source power is a reverse polarity
condition, the EMS will not allow power
to the RV and the error code will read
E1.
 |
Open Neutral Protection: |
 |
If the source has an open neutral
condition the display will not appear,
and will not allow power to the RV.
 |
Open Ground Protection:
|
 |
If source power has an open ground
condition, the EMS will read an
error code of E2 and will not allow
power to the RV.
 |
AC
Frequency Protection: |
 |
If source power frequency deviates by
(+/-) 9 hertz from 60 cycles per second, the EMS
will shut down source power, and
indicate an E7 or E8 error code on the digital
display.
 |
Accidental 220V Protection:
|
 |
If 220 volts is detected when plugging
into source power the EMS will not allow
power to the RV. If this condition
occurs while power is applied to the RV,
the EMS shuts off power instantly.
The display will read the
voltage and the appropriate error code.
 |
Integrated Information Panel: |
 |
Scrolls continuously through all of the
power source information: voltage,
current, frequency, error codes, and
previous errors. Each reading is
displayed for 2 seconds.
 |
Previous Error Code: |
 |
This feature tells the user why the EMS
previously interrupted power to the RV.
This is only displayed if an error
actually occurs, and resets when power
is disconnected to the EMS.
 |
Weather Resistant: |
 |
Can be exposed to elements, but may not
be submerged.
 |
Microprocessor Controlled: |
 |
The
computer is driven by state of the art
microprocessors that are programmed with
software to drive the entire EMS.
 |
Lock Bracket: |
 |
Allows the
user to secure the unit to power source
to prevent theft.
Return