Voltage Protection: |
 |
Whenever
source power falls below 104 Volts, or
rises above 132 volts, the EMS
automatically shuts down power to the RV.
Once the AC source rises above 104-volts, or
below the 132-volt level, the time delay
indicator flashes for the preset time and then
automatically restores power to RV.
 |
Time Delay for A/C Compressor: |
 |
Whenever
source power is interrupted by
the source or the EMS due to a fault
condition, the built in time delay is
activated. There are two settings on the
EMS; one is 136 seconds, and the other
is 15 seconds. Consult you Air
Conditioner manual to see if it has a
time delay built in. If yes, use the 15-second delay.
If no, use the 136-second delay.
 |
Three(3)-Mode Surge Protection: |
 |
This
feature provides full surge protection:
L-N, L-G, and N-G. Total Joule rating is
1780, response time of <1 nano second.
 |
Surge Indicator: |
 |
If ever
a power surge damages the surge
protector circuit within the EMS L-N, or L-G, the
digital display error code will read E-10. This
is your indication that it needs to be replaced.
 |
Reverse Polarity Protection: |
 |
If
source power is a reverse polarity
condition, the EMS will not allow power
to the RV and the error code will read
E1.
 |
Open Neutral Protection: |
 |
If the source has an open neutral
condition the display will not appear,
and will not allow power to the RV.
 |
Open Ground Protection:
|
 |
If source power has an open ground
condition, the EMS will read an
error code of E2 and will not allow
power to the RV.
 |
AC
Frequency Protection: |
 |
If source power frequency deviates by
(+/-) 9 hertz from 60 cycles per second, the EMS
will shut down source power, and
indicate an E7 or E8 error code on the digital
display.
 |
Accidental 220V Protection:
|
 |
If 220 volts is detected when plugging
into source power the EMS will not allow
power to the RV. If this condition
occurs while power is applied to the RV,
the EMS shuts off power instantly.
In either case the display will read the
voltage and E3 or E5 will be displayed
depending on the error code.
 |
Remote Display: |
 |
Scrolls continuously through all of the
power source information: voltage,
current, frequency, error codes, and
previous errors. Each reading is
displayed for 2 seconds.
 |
Previous Error Code: |
 |
This feature tells the user why the EMS
previously interrupted power to the RV.
This is only displayed if an error
actually occurs, and resets when power
is disconnected to the EMS.
 |
Bypass Switch: |
 |
Enclosed blue jumper wire allows the
user to bypass the computer circuit in
the EMS in the event of computer
failure, thus allowing source power into
the RV. This does not disable the
surge protection portion of the EMS.
 |
Modular Design: |
 |
Replacement parts are designed for
simple plug and play, making repairs
extremely user friendly.
 |
Microprocessor Controlled: |
 |
The
computer is driven
by state of the art microprocessors that
are programmed with software to drive
the entire EMS. Should ever this
software be changed, EMS owners can
receive a free upgrade processor with
the return of the old.